PACK SIZE 20 plugs / box
PACKAGING Non-sterile
SIZES S / M / L / X-Large
MATERIAL Medical-grade silicone
➤ Designed for effective dry eye relief, these punctal plugs help reduce tear drainage for long-lasting moisture retention.
➤ Bulk pack of 20 — non-sterile, made from high-quality medical-grade silicone and available in multiple sizes for a precise fit.
➤ Reliable and cost-effective for high-volume use, ensuring consistent performance. Backed by our 30-day free returns for complete peace of mind.
Product Description
VeraPlug™ is designed to provide a simple and effective treatment for chronic dry eye.
➤ Packaged non-sterile — 1 pair per poly bag, 10 pairs per box.
➤ Sterile inserters included.
➤ Conforms perfectly to the puncta for unparalleled retention.
➤ Low-profile dome for enhanced patient comfort.
➤ Proprietary shaft design for easy insertion and proper anatomic fit.
➤ Available in four sizes — Small, Medium, Large, X-Large.
➤ Box of 20 plugs.
➤ Easy to use.
Size Chart
| PUNCTAL OPENING | VERAPLUG™ SIZE |
| 0.4 mm to 0.6 mm |
Small |
| 0.6 mm to 0.7 mm |
Medium |
| 0.7 mm to 0.8 mm |
Large |
| 0.8 mm to 1.0 mm |
X-Large |
CLINICAL REFERENCE
VeraPlug™ Instructions for Use
Important: Always refer to the insert in the box for the latest information.
Description
The VeraPlug™ punctal occluder is designed to provide reduction or elimination of tear drainage through the inferior or superior puncta, thus maintaining lubricating tears on the surface of the eye. Each VeraPlug™ punctal occluder is molded from medical-grade silicone. The VeraPlug™ is available in four sizes (small, medium, large, and x-large).
Indications for Use
The VeraPlug™ is for use in patients with dry eye syndromes.
Contraindications
Contraindications include, but are not limited to: eye infections, sensitivity or allergies to the occluder material and/or materials used in the manufacture of the device, blockage or infection of the lacrimal systems, inflammation of the eyelid, and epiphora.
Precautions
The VeraPlug™ may enhance the effect of some ocular medications in the eye. Depending on the type of medication being used, the dose may need to be altered accordingly. If the patient experiences irritation, infection, or epiphora after the insertion of the VeraPlug™, the occluder should be removed.
Potential Adverse Events
The following complications may occur:
- Epiphora
- Pyogenic granuloma
- Foreign body sensation
- Infection of the lacrimal system
- Plug dislodgement or migration possibly requiring surgical intervention
- Washout
- Punctal erosion
Product Features
Each box contains ten pairs of VeraPlug™ punctal occluders for single use only. The VeraPlug™ is manufactured from implant-grade silicone.
Proper Sizing
The VeraPlug™ punctal occluder is available in four sizes: small, medium, large, and x-large. To determine the proper size, begin with the smallest VeraPlug™ gauge (0.5 mm) and insert the head of the gauge into the punctal opening. The gauge should fit snugly with a small amount of resistance. If the gauge enters the punctal opening with no resistance, the next larger size gauge should be tried in the same manner. Repeat this process until the proper size VeraPlug™ is determined based on the size chart shown above.
Sterilization
Remove the occluders to be sterilized from the bag using forceps. Grasp the occluder at the shaft, place into an autoclavable pouch and seal. The VeraPlug™ can be sterilized using steam gravity type sterilization. The cycle temperature is 121°C (250°F) and cycle time is 30 minutes. The dry time is an additional 30 minutes. The entire cycle meets a SAL (Sterility Assurance Level) of 10⁻⁶.
Loading
Load the sterilized occluder onto the sterile inserter using forceps. Grip the occluder by its shaft and carefully guide the inserter wire into the hole on the occluder cap. Secure the occluder on the inserter wire by placing the forceps onto the nose portion of the plug and pushing gently. The occluder is properly loaded when the wire has reached the end of the shaft to the point where it begins to taper.
Prior to Insertion
Patients with intermittent tearing should receive probing and irrigation with a sterile irrigation solution to rule out pre-existing canalicular obstruction.
Insertion
- Anesthetize the area of the punctum with a topical anesthetic placed in the conjunctival sac.

- Apply a drop of saline solution or artificial tears onto the VeraPlug™ to help ease insertion.
- Position the insertion instrument by placing the forefinger on the release button of the inserter and placing the occluder end of the insertion instrument over the patient's (superior or inferior) punctum.
- Vertically insert the VeraPlug™ by positioning the occluder into the punctum until the cap is flush with the punctal opening. (Figure A)
- When the occluder is properly seated, depress the release button and withdraw the insertion instrument. (Figure B)
- Verify that the occluder is properly placed by confirming that the cap is flush with the punctal opening. (Figure C) After insertion, monitor the placement and integrity of the occluder to determine if and when the occluder may need to be replaced.
Removal
Should removal be indicated, grasp the vertical shaft of the occluder underneath the exposed cap with sterile forceps. Gently pull upward until the plug is removed. (Figure D)
Storage
Store at room temperature.
Warnings
The VeraPlug™ punctal occluder is intended for single use. Do not reuse. If the sterile packaging is damaged or opened, sterility is not guaranteed and the VeraPlug™ should be discarded. U.S. federal law restricts the sale of this device by or on the order of a physician.
Documentation
Each box contains Instructions for Use and 20 labels for your ease and convenience.
Clinician Use Only: All products sold on AccuSpire.com should be used by a qualified clinician and should be purchased by or on the order of a qualified clinician.